top of page

Construction ID: ECO-20U

Engineer timber floor

Direct, floating installation

System IDEAL EPS 150 kPa

UDL

2.0 kN/m²

T&G floating engineered timber

Construction height

3mm

UFH compatible underlay

JUPITER IDEAL ECO

Perimeter support batten

Perimeter insulation

Moisture barrier (if required)

30mm

≤20mm

30mm

Technical Data

Construction suitable for floors with significant heat loss below

Construction height*

Mass

Thermal resistance R

mm

kg/m²

m²K/W

30

8

0.75

Height excluding floor finish

Mass excluding floor finish

Part L compliant for floors above heated rooms

.zip includes:

.PDF

NBS Spec

.DWG

Uniform Distributed Load (UDL)

Point load (≥ 20cm²)

Impact sound reduction

Area of application

Floors with rooms of equal

temperature above & below

Rmin=0,75 m²K/W

Additional information

kN/m²

2.5

kN

2.0

dB

<21

Valid on concrete floors >12cm | (DIN EN 4109: m² > 276kg/m²)

This construction is suitable for use on intermediate floors, no further insulation is needed to meet the requirements of Approved Document L.

 

For ground floor installations refer instead to construction ID ECO-20G

Substrate must be solid, level and flat so that the heating elements can lie flat. Tolerance required as per Surface Regularity 1. (+/- 3mm over 2m)

bottom of page