Construction ID: ECO-20U









Engineer timber floor
Direct, floating installation
System IDEAL EPS 150 kPa

UDL
2.0 kN/m²

T&G floating engineered timber
Construction height
3mm
UFH compatible underlay
JUPITER IDEAL ECO
Perimeter support batten
Perimeter insulation
Moisture barrier (if required)
30mm
≤20mm
30mm
Technical Data
Construction suitable for floors with significant heat loss below
Construction height*
Mass
Thermal resistance R
mm
kg/m²
m²K/W
30
8
0.75
Height excluding floor finish
Mass excluding floor finish
Part L compliant for floors above heated rooms
.zip includes:
NBS Spec
.DWG
Uniform Distributed Load (UDL)
Point load (≥ 20cm²)
Impact sound reduction
Area of application
Floors with rooms of equal
temperature above & below
Rmin=0,75 m²K/W
Additional information
kN/m²
2.5
kN
2.0
dB
<21
Valid on concrete floors >12cm | (DIN EN 4109: m² > 276kg/m²)
This construction is suitable for use on intermediate floors, no further insulation is needed to meet the requirements of Approved Document L.
For ground floor installations refer instead to construction ID ECO-20G
Substrate must be solid, level and flat so that the heating elements can lie flat. Tolerance required as per Surface Regularity 1. (+/- 3mm over 2m)