Construction ID: ECO-50U









Tile / stone / timber / laminates / synthetics
Jupiter DimaMat System
System IDEAL ECO 150 kPa

UDL
2.0 kN/m²

Floor finish
Construction height
JUPITER DimaMat system
JUPITER IDEAL ECO
Perimeter support batten
Perimeter insulation
Moisture barrier (if required)
3mm
30mm
33mm
Technical Data
Construction suitable for floors between rooms of equal temperature
Construction height
Mass
Thermal resistance R
mm
kg/m²
m²K/W
33
13
0.75
Height excluding floor finish
Mass excluding floor finish
Part L compliant for floors above heated rooms
.zip includes:
NBS Spec
.DWG
Uniform Distributed Load (UDL)
Point load (≥ 20cm²)
Impact sound reduction
Area of application
Floors with rooms of equal
temperature above & below
Rmin=0,75 m²K/W
Additional information
kN/m²
2.0
kN
1.5
dB
≤28
Valid on concrete floors >12cm | (DIN EN 4109: m² > 276kg/m²)
This construction is suitable for use on intermediate floors, no further insulation is needed to meet the requirements of Approved Document L.
For ground floor installations refer instead to construction ID ECO-50G
Substrate must be solid, level and flat so that the heating elements can lie flat. Tolerance required as per Surface Regularity 1. (+/- 3mm over 2m)
Installation environment must be min. +4°C max. +30°C
DimaMat format: Roll 1000mm x 2000mm x 1.2mm