Construction ID: ECO-60G









Solid timber floor
Direct installation (fixed to battens)
System IDEAL ECO 150 kPa

UDL
2.0 kN/m²

Floor finish
Construction height
30mm
JUPITER IDEAL ECO
Support batten
Perimeter support batten
Perimeter insulation
Primary insulation i.e Kingspan
18mm
98 - 148mm
Technical Data
Construction suitable for floors with significant heat loss below
Construction height*
mm
98-148
Height excluding floor finish
Mass*
kg/m²
23-25
Mass excluding floor finish
Thermal resistance, R-value**
m²K/W
0.75
.zip includes:
NBS Spec
.DWG
Uniform Distributed Load (UDL)
Point load (≥ 20cm²)
Impact sound reduction
Area of application
Ground floors or floors located above unheated rooms such as garages, basements etc.
Additional information
kN/m²
2.0
kN
2.0
dB
-
* Based on 50-100mm Kingspan Kooltherm K103
** R-value of JUPITER IDEAL system only
For upper floor installations refer instead to construction ECO-60U.
Substrate must be solid, level and flat so that the heating elements can lie flat. Tolerance required as per Surface Regularity 1. (+/- 3mm over 2m)