Construction ID: ECO-60U









Solid timber floor
Direct installation (fixed to battens)
System IDEAL ECO 150 kPa

UDL
3.0 kN/m²

Floor finish
Construction height
JUPITER IDEAL ECO
Support batten
Perimeter support batten
Perimeter insulation
Moisture barrier (if required)
30mm
≤22mm
≤52mm
Technical Data
Construction suitable for floors with significant heat loss below
Construction height
Mass
Thermal resistance, R-value
Uniform Distributed Load (UDL)
Point load (≥ 20cm²)
Impact sound reduction
Area of application
Floors with rooms of equal
temperature above & below
Rmin=0,75 m²K/W
Additional information
mm
kg/m²
m²K/W
≤52
8
0.75
Height excluding floor finish
Mass excluding floor finish
Part L compliant for floors above heated rooms
.zip includes:
NBS Spec
.DWG
kN/m²
3.0
kN
2.5
dB
≤21
Valid on concrete floors >12cm | (DIN EN 4109: m² > 276kg/m²)
This construction is suitable for use on intermediate floors, no further insulation is needed to meet the requirements of Approved Document L.
For ground floor installations refer instead to construction ID ECO-60G
Substrate must be solid, level and flat so that the heating elements can lie flat. Tolerance required as per Surface Regularity 1. (+/- 3mm over 2m)