Construction ID: ECO-70U

Adhered timber / tile / synthetics

Jupiter Firmax CP

System IDEAL ECO 150 kPa

UDL

4.0 kN/m²

Floor finish

Construction height

JUPITER Firmax CP

JUPITER IDEAL ECO

Perimeter support batten

Perimeter insulation

Moisture barrier (if required)

12mm

30mm

 ≤42mm

Technical Data

Construction suitable for floors with significant heat loss below

Construction height

Mass

Thermal resistance, R-value

mm

kg/m²

m²K/W

42

29

0.75

Height excluding floor finish

Mass excluding floor finish

Part L compliant for floors above heated rooms

.zip includes:

.PDF

NBS Spec

.DWG

Uniform Distributed Load (UDL)

Point load (≥ 20cm²)

Impact sound reduction

Area of application

Floors with rooms of equal

temperature above & below

Rmin=0,75 m²K/W

Additional information

kN/m²

4.0

kN

4.0

dB

≤21

Valid on concrete floors >12cm | (DIN EN 4109: m² > 276kg/m²)

This construction is suitable for use on intermediate floors, no further insulation is needed to meet the requirements of Approved Document L.

 

For ground floor installation refer instead to construction ID ECO-70G

Substrate must be solid, level and flat so that the heating elements can lie flat. Tolerance required as per Surface Regularity 1. (+/- 3mm over 2m)

 

Installation environment must be min. +12°C max. +30°C

 

Firmax CP product format: 1200mm x 600mm x 12mm (2no layers @ 6mm)

Firmax CP mass: 21kg/m²

Firmax CP thermal resistance: 0.038m²K/W