Construction ID - ECO-BJ1G

Solid / engineered timber floors

Direct, fixed installation

System IDEAL ECO 150 kPa

UDL

3.0 kN/m²

Timber floors

Construction height

JUPITER IDEAL ECO

Supporting ply

Supporting batten

Joist

Primary insulation

18mm

30mm

0mm

Technical Data

Construction suitable for floors above uninsulated or unheated space

Construction height

Mass

Thermal resistance, R-value**

Uniform Distributed Load (UDL)

Point load (≥ 20cm²)

Impact Sound reduction

Area of application

Ground floors or floors located above unheated rooms such as garages, basements etc.

Installation information

mm

kg/m²

m²K/W

0

18-28

0.75

System sits between joists avoiding height

Mass excluding floor finish

Part L with correct amount of additional insulation

.zip includes:

.PDF

NBS Spec

.DWG

kN/m²

3.0

kN

3.0

dB

-

This construction is valid for floor constructions located above uninsulated or unheated space

* Based on 50mm & 100mm rigid wood fibre insulation

** R-value of JUPITER IDEAL system only

 

For upper floor installation see construction ECO-BJ1U.

When installing timber floors without tongue and groove edges it is advised to install building paper or similar under timber floor as possible shrinkage of timber will expose aluminium diffuser plates beneath.

 

Glue and screw supporting ply to battens.

 

Aluminium diffuser plates should be flush with top of joists.

  • White Facebook Icon
  • White Twitter Icon
  • White Instagram Icon

@JupiterUFH

Jupiter Heating Systems Ltd. 2018 | Unit 1, The Barns, Pennypot Lane, Chobham, Woking, Surrey, United Kingdom, GU24 8DJ

Company No. 05273967 | VAT No. GB 849 3471 91 | Registered in the United Kingdom| Terms of Use | Privacy