top of page

Construction ID - ECO-BJ1U

Solid / engineered timber floors

Direct, fixed installation

System IDEAL ECO 150 kPa

UDL

3.0 kN/m²

Timber floors

Construction height

JUPITER IDEAL ECO

Supporting ply

Supporting batten

Joist

18mm

30mm

0mm

Technical Data

Construction suitable for floors between rooms of equal temperature

Construction height

Mass

Thermal resistance, R-value

mm

kg/m²

m²K/W

0

8

0.75

System sits between joists avoiding height

Mass without floor finish

Part L compliant for floors above heated rooms

.zip includes:

.PDF

NBS Spec

.DWG

Uniform Distributed Load (UDL)

Point load (≥ 20cm²)

Impact sound reduction

Area of application

Floors with rooms of equal

temperature above & below

Rmin=0,75 m²K/W

Additional information

kN/m²

3.0

kN

3.0

dB

-

This construction is valid for floor constructions located between rooms heated to equal or similar temperature. No further insulation is required to meet Part L requirements.

 

For ground floor installation see construction ECO-BJ1G.

When installing timber floors without tongue and groove edges it is advised to install building paper or simialar under timber floor as possible shrinkage of timber will expose aluminium diffuser plates beneath.

 

Glue and screw supporting ply to battens.

 

Aluminium diffuser plates should be flush with top of joists.