top of page

Construction ID - ECO-BJ2U

All floor finishes

Screed Replacement Tile

System IDEAL ECO 150 kPa

UDL

5.0 kN/m²

Screed Replacement Tile

Construction height

JUPITER IDEAL ECO

Supporting ply

Supporting batten

Joist

18mm

30mm

18mm

18mm

Technical Data

Construction suitable for floors between rooms of equal temperature

Construction height

Mass

Thermal resistance, R-value

Point load (≥ 20cm²)*

Impact sound reduction

Area of application

Floors with rooms of equal

temperature above & below

Rmin=0,75 m²K/W

Additional information

mm

18

System height based on S.R.T. thickness

kg/m²

43

Mass excluding floor finish

m²K/W

0.75

kN

5.0

dB

-

.zip includes:

.PDF

NBS Spec

.DWG

This construction is valid for floor constructions located between rooms heated to equal or similar temperature. No further insulation is required to meet Part L requirements.

*Joist integrity dependent

For ground floor installation see construction ECO-BJ2G.

When installed the Screed Replacement Tiles may follow any undulation that occurs from the joists. This may need to be taken out with the use of a thin levelling compound.

 

Aluminium diffuser plates should be flush with top of joists.