top of page

Construction ID - ECO-BJ3G

All floor finishes*

Fermacell 2E11

System IDEAL ECO 150 kPa

UDL

2.0 kN/m²

Fermacell 2E11

Construction height

JUPITER IDEAL ECO

Supporting ply

Supporting batten

Joist

Primary insulation

18mm

30mm

20mm

20mm

Technical Data

Construction suitable for floors above uninsulated or unheated space

Construction height

mm

20

System height based on Fermacell thickness

Mass

kg/m²

41-51

Mass without floor finish

Thermal resistance, R-value**

m²K/W

3.30

Part L with correct amount of

additional insulation

.zip includes:

.PDF

NBS Spec

.DWG

Uniform Distributed Load (UDL)

Point load (≥ 20cm²)**

Impact Sound reduction

Area of application

Ground floors or floors located above unheated rooms such as garages, basements etc.

Additional information

kN/m²

2.0

kN

2.0

dB

n/a

This construction is valid for floor constructions located above un-insulated or unheated space

* Based on 50mm & 100mm rigid wood fibre insulation

** R-value of JUPITER IDEAL system only

 

For upper floor installation see construction ECO-BJ3U.

When installed the Fermacell elements may follow any undulation that occurs from the joists. This may need to be taken out with the use of a thin levelling compound.

 

Aluminium diffuser plates should be flush with top of joists.

 

*Caution with tile and stone