top of page

Construction ID: EPS-10G

Carpet / tile / timber / laminates / synthetics

Fermacell 2E11 / Gypsum fibre board

2.0 kN/m²

Construction height

System IDEAL EPS 240 kPa

20mm

30mm

Floor finish

Fermacell 2E11

JUPITER IDEAL EPS

Perimeter support batten

Perimeter insulation

Primary insulation i.e. Kingspan

UDL

100 - 150mm

Technical Data

Construction suitable for floors with significant heat loss below

Construction height*

Mass*

Thermal resistance, R-value**

Uniform Distributed Load (UDL)

Point load (≥ 20cm²)

Impact sound reduction

Area of application

Ground floors or floors located above unheated rooms such as garages, basements etc.

Additional information

Working in conjunction with

mm

100 - 150

Height excluding floor finish

kg/m²

27-29

Mass excluding floor finish

m²K/W

0.86

kN/m²

2.0

kN

2.0

dB

-

.zip includes:

.PDF

NBS Spec

.DWG

* Based on 50mm & 100mm Kingspan Kooltherm K103

** R-value of JUPITER IDEAL system only

 

For upper floor installations refer instead to construction ID EPS-10U.

Substrate must be solid, level and flat so that the heating elements can lie flat. Tolerance required as per Surface Regularity 1. (+/- 3mm over 2m)

 

Installation environment must be min. +10°C max. 40°C

 

Fermacell product format: 1500mm x 500mm x 20mm

UDL & point load tested with Kingspan Kooltherm K103 ≤ 100mm

 

Caution – restrictions apply to maximum tile & stone sizes on Fermacell

bottom of page