Construction ID: EPS-10U









Carpet / tiles / timber / laminates / synthetics
Fermacell 2E11 / Gypsum fibre board
System IDEAL EPS 240 kPa

UDL
2.0 kN/m²
Floor finish
Construction height
20mm
30mm
Fermacell 2E11
JUPITER IDEAL EPS
Perimeter support batten
Perimeter insulation
Moisture barrier (if required)

50mm
Technical Data
Construction suitable for rooms on intermediate floors
Construction height
Mass
Thermal resistance, R-value
Uniform Distributed Load (UDL)
Point load (≥ 20cm²)
Impact sound reduction
Area of application
Floors with rooms of equal
temperature above & below
Rmin=0,75 m²K/W
Additional information
mm
50
Height excluding floor finish
kg/m²
26
Mass excluding floor finish
m²K/W
0.86
Part L compliant for floors above heated rooms
kN/m²
2.0
kN
2.0
dB
-
This construction is suitable for use on intermediate floors, no further insulation is needed to meet the requirements of Approved Document L.
For ground floor installations refer instead to construction ID EPS-10G.
Substrate must be solid, level and flat so that the heating elements can lie flat. Tolerance required as per Surface Regularity 1. (+/- 3mm over 2m)
Fermacell elements are glued & screwed / stapled together as a floating floor.
Installation environment must be min. +10°C max. 40°C
Fermacell material format: 1500mm x 500mm x 20mm
Caution – restrictions apply to maximum tile & stone sizes on Fermacell
.zip includes:
NBS Spec