top of page

Construction ID: EPS-10U

Carpet / tiles / timber / laminates / synthetics

Fermacell 2E11 / Gypsum fibre board

System IDEAL EPS 240 kPa

UDL

2.0 kN/m²

Floor finish

Construction height

20mm

30mm

Fermacell 2E11

JUPITER IDEAL EPS

Perimeter support batten

Perimeter insulation

Moisture barrier (if required)

50mm

Technical Data

Construction suitable for rooms on intermediate floors

Construction height

Mass

Thermal resistance, R-value

Uniform Distributed Load (UDL)

Point load (≥ 20cm²)

Impact sound reduction

Area of application

Floors with rooms of equal

temperature above & below

Rmin=0,75 m²K/W

Additional information

mm

50

Height excluding floor finish

kg/m²

26

Mass excluding floor finish

m²K/W

0.86

Part L compliant for floors above heated rooms

kN/m²

2.0

kN

2.0

dB

-

This construction is suitable for use on intermediate floors, no further insulation is needed to meet the requirements of Approved Document L.

 

For ground floor installations refer instead to construction ID EPS-10G.

Substrate must be solid, level and flat so that the heating elements can lie flat. Tolerance required as per Surface Regularity 1. (+/- 3mm over 2m)

 

Fermacell elements are glued & screwed / stapled together as a floating floor.

 

Installation environment must be min. +10°C max. 40°C

 

Fermacell material format: 1500mm x 500mm x 20mm

 

Caution – restrictions apply to maximum tile & stone sizes on Fermacell

.zip includes:

.PDF

NBS Spec

.DWG

bottom of page