top of page

Construction ID: EPS-20U

Engineered timber floor

Floating floor installation

System IDEAL EPS 240 kPa

UDL

2.0 kN/m²

Floor finish

UFH compatible underlay

JUPITER IDEAL EPS

Perimeter support batten

Perimeter insulation

Moisture barrier (if required)

Construction height

3mm

30mm

≤20mm

53mm

Technical Data

Construction suitable for rooms on intermediate floors

Construction height

Mass

Thermal resistance, R-value

Uniform Distributed Load (UDL)

Point load (≥ 20cm²)

Impact sound reduction

Area of application

Floors with rooms of equal

temperature above & below

Rmin=0,75 m²K/W

Additional information

mm

53

Height including floor finish

kg/m²

3

Mass excluding floor finish

m²K/W

0.86

Part L compliant for floors above heated rooms

kN/m²

2.0

kN

2.0

dB

-

This construction is suitable for use on intermediate floors, no further insulation is needed to meet the requirements of Approved Document L.

 

For ground floor installations refer instead to construction ID EPS-20G.

Substrate must be solid, level and flat so that the heating elements can lie flat. Tolerance required as per Surface Regularity 1. (+/- 3mm over 2m)