Construction ID: EPS-30G










Carpet / tiles / timber / laminates / synthetics
Liquid anhydrite screed
System IDEAL EPS 240 kPa

UDL
2.0 kN/m²

Construction height
35mm
30mm
Floor finish
Anhydrite screed
JUPITER system foil
Perimeter support batten
Perimeter insulation
JUPITER IDEAL EPS
Primary insulation i.e. Kingspan
115-165mm
Technical Data
Construction suitable for floors with significant heat loss below
Construction height*
Mass*
Thermal resistance, R-value**
Uniform Distributed Load (UDL)
Point load (≥ 20cm²)
Impact sound reduction
Area of application
Ground floors or floors located above unheated rooms such as garages, basements etc.
Additional information
mm
115-165
Height excluding floor finish
kg/m²
~75
Mass excluding floor finish
m²K/W
0.86
kN/m²
2.0
kN
1.0
dB
-
* Based on 50mm & 100mm Kingspan Kooltherm K103
** R-value of JUPITER IDEAL system only
For upper floor installations refer instead to construction ID EPS-30U.
Substrate must be solid, level and flat so that the heating elements can lie flat. Tolerance required as per Surface Regularity 1. (+/- 3mm over 2m)
UDL & point load tested with Kingspan Kooltherm K103 ≤ 100mm
Working in conjunction with

.zip includes:
NBS Spec
.DWG