top of page

Construction ID: EPS-30U

Carpet / tile / timber / laminates / synthetics

Liquid anhydrite screed

System IDEAL EPS 240 kPa

UDL

2.0 kN/m²

Anhydrite screed

Construction height

30mm

System foil and edging tape

JUPITER IDEAL EPS

Perimeter support batten

Perimeter insulation

Moisture barrier (if required)

35mm

65mm

Technical Data

Construction suitable for rooms on intermediate floors

Construction height

Mass

Thermal resistance, R-value

Uniform Distributed Load (UDL)

Point load (≥ 20cm²)

Impact sound reduction

Area of application

Floors with rooms of equal

temperature above & below

Rmin=0,75 m²K/W

Additional information

mm

kg/m²

m²K/W

kN/m²

65

~75

0.86

2.0

Height excluding floor finish

Mass excluding floor finish

Part L compliant for floors above heated rooms

.zip includes:

.PDF

NBS Spec

.DWG

kN

1.0

dB

-

This construction is suitable for use on intermediate floors, no further insulation is needed to meet the requirements of Approved Document L.

 

For ground floor installation see construction EPS-30G.

Substrate must be solid, level and flat so that the heating elements can lie flat. Tolerance required as per Surface Regularity 1. (+/- 3mm over 2m)