top of page

Construction ID: EPS-50G

Tile / stone

Jupiter DimaMat System

System IDEAL EPS 240 kPa

UDL

2.0 kN/m²

Construction height

3mm

30mm

Floor finish

JUPITER DimaMat system

JUPITER IDEAL EPS

Perimeter support batten

Perimeter insulation

Primary insulation i.e. Kingspan

83 - 133mm

Technical Data

Construction suitable for floors with significant heat loss below

Construction height*

Mass*

Thermal resistance, R-value**

Uniform Distributed Load (UDL)

Point load (≥ 20cm²)

Impact sound reduction

Area of application

Ground floors or floors located above unheated rooms such as garages, basements etc.

Additional information

Working in conjunction with

mm

83-133

Height excluding floor finish

kg/m²

10-12

Mass excluding floor finish

m²K/W

0.86

kN/m²

2.0

kN

1.5

dB

-

* Based on 50mm & 100mm Kingspan Kooltherm K103

** R-value of JUPITER IDEAL system only

 

For upper floor installations refer instead to construction ID EPS-50U.

Substrate must be solid, level and flat so that the heating elements can lie flat. Tolerance required as per Surface Regularity 1. (+/- 3mm over 2m)

 

Installation environment must be minimum +5°C

 

UDL & point load tested with Kingspan Kooltherm K103 ≤ 100mm

.zip includes:

.PDF

NBS Spec

.DWG

bottom of page