Construction ID: EPS-50G









Tile / stone
Jupiter DimaMat System
System IDEAL EPS 240 kPa

UDL
2.0 kN/m²
Construction height
3mm
30mm
Floor finish
JUPITER DimaMat system
JUPITER IDEAL EPS
Perimeter support batten
Perimeter insulation
Primary insulation i.e. Kingspan

83 - 133mm
Technical Data
Construction suitable for floors with significant heat loss below
Construction height*
Mass*
Thermal resistance, R-value**
Uniform Distributed Load (UDL)
Point load (≥ 20cm²)
Impact sound reduction
Area of application
Ground floors or floors located above unheated rooms such as garages, basements etc.
Additional information
Working in conjunction with

mm
83-133
Height excluding floor finish
kg/m²
10-12
Mass excluding floor finish
m²K/W
0.86
kN/m²
2.0
kN
1.5
dB
-
* Based on 50mm & 100mm Kingspan Kooltherm K103
** R-value of JUPITER IDEAL system only
For upper floor installations refer instead to construction ID EPS-50U.
Substrate must be solid, level and flat so that the heating elements can lie flat. Tolerance required as per Surface Regularity 1. (+/- 3mm over 2m)
Installation environment must be minimum +5°C
UDL & point load tested with Kingspan Kooltherm K103 ≤ 100mm
.zip includes:
NBS Spec
.DWG