Construction ID: EPS-50U









Tile / stone
Jupiter DimaMat System
System IDEAL EPS 240 kPa

UDL
2.0 kN/m²

Floor finish
Construction height
3mm
Jupiter DimaMat system
JUPITER IDEAL EPS
Perimeter support batten
Perimeter insulation
Moisture barrier (if required)
30mm
33mm
Technical Data
Construction suitable for rooms on intermediate floors
Construction height
mm
33
Height excluding floor finish
Mass
kg/m²
8
Mass excluding floor finish
Thermal resistance, R-value
m²K/W
0.86
Part L compliant for floors above heated rooms
.zip includes:
NBS Spec
.DWG
Uniform Distributed Load (UDL)
Point load (≥ 20cm²)
Impact sound reduction
Area of application
Floors with rooms of equal
temperature above & below
Rmin=0,75 m²K/W
Additional information
kN/m²
2.0
kN
1.5
dB
-
This construction is suitable for use on intermediate floors, no further insulation is needed to meet the requirements of Approved Document L.
For ground floor installations refer instead to construction ID EPS-50G.
Substrate must be solid, level and flat so that the heating elements can lie flat. Tolerance required as per Surface Regularity 1. (+/- 3mm over 2m)
Installation environment must be minimum +5°C
DimaMat format: Roll 1m x 20m x 1.2mm