top of page

Construction ID: EPS-50U

Tile / stone

Jupiter DimaMat System

System IDEAL EPS 240 kPa

UDL

2.0 kN/m²

Floor finish

Construction height

3mm

Jupiter DimaMat system

JUPITER IDEAL EPS

Perimeter support batten

Perimeter insulation

Moisture barrier (if required)

30mm

33mm

Technical Data

Construction suitable for rooms on intermediate floors

Construction height

mm

33

Height excluding floor finish

Mass

kg/m²

8

Mass excluding floor finish

Thermal resistance, R-value

m²K/W

0.86

Part L compliant for floors above heated rooms

.zip includes:

.PDF

NBS Spec

.DWG

Uniform Distributed Load (UDL)

Point load (≥ 20cm²)

Impact sound reduction

Area of application

Floors with rooms of equal

temperature above & below

Rmin=0,75 m²K/W

Additional information

kN/m²

2.0

kN

1.5

dB

-

This construction is suitable for use on intermediate floors, no further insulation is needed to meet the requirements of Approved Document L.

 

For ground floor installations refer instead to construction ID EPS-50G.

Substrate must be solid, level and flat so that the heating elements can lie flat. Tolerance required as per Surface Regularity 1. (+/- 3mm over 2m)

 

Installation environment must be minimum +5°C

 

DimaMat format: Roll 1m x 20m x 1.2mm