Construction ID: EPS-60G









Solid timber floor
Direct installation (fixed to battens)
System IDEAL EPS 240 kPa

UDL
3.0 kN/m²
Solid timber
Construction height
30mm
≤22mm
JUPITER IDEAL EPS
Support batten
Perimeter support batten
Intermediate supporting ply
Primary insulation i.e. Kingspan

18mm
98-148mm
Technical Data
Construction suitable for floors with significant heat loss below
Construction height*
Mass*
Thermal resistance, R-value**
Uniform Distributed Load (UDL)
Point load (≥ 20cm²)
Impact sound reduction
Area of application
Ground floors or floors located above unheated rooms such as garages, basements etc.
Additional information
mm
98-148
Height excluding floor finish
kg/m²
18-20
Mass excluding floor finish
m²K/W
0.86
kN/m²
3.0
kN
2.0
dB
-
* Based on 50mm & 100mm Kingspan Kooltherm K103
** R-value of JUPITER IDEAL system only
For upper floor installations refer instead to construction ID EPS-60U.
Substrate must be solid, level and flat so that the heating elements can lie flat. Tolerance required as per Surface Regularity 1. (+/- 3mm over 2m)
UDL & point load tested with Kingspan Kooltherm K103 ≤ 100mm