top of page

Construction ID: EPS-60G

Solid timber floor

Direct installation (fixed to battens)

System IDEAL EPS 240 kPa

UDL

3.0 kN/m²

Solid timber

Construction height

30mm

≤22mm

JUPITER IDEAL EPS

Support batten

Perimeter support batten

Intermediate supporting ply

Primary insulation i.e. Kingspan

18mm

98-148mm

Technical Data

Construction suitable for floors with significant heat loss below

Construction height*

Mass*

Thermal resistance, R-value**

Uniform Distributed Load (UDL)

Point load (≥ 20cm²)

Impact sound reduction

Area of application

Ground floors or floors located above unheated rooms such as garages, basements etc.

Additional information

mm

98-148

Height excluding floor finish

kg/m²

18-20

Mass excluding floor finish

m²K/W

0.86

kN/m²

3.0

kN

2.0

dB

-

* Based on 50mm & 100mm Kingspan Kooltherm K103

** R-value of JUPITER IDEAL system only

 

For upper floor installations refer instead to construction ID EPS-60U.

Substrate must be solid, level and flat so that the heating elements can lie flat. Tolerance required as per Surface Regularity 1. (+/- 3mm over 2m)

 

UDL & point load tested with Kingspan Kooltherm K103 ≤ 100mm