top of page

Construction ID: EPS-60U

Solid timber floor

Direct installation (fixed to battens)

System IDEAL EPS 240 kPa

UDL

2.0 kN/m²

Floor finish

JUPITER IDEAL EPS

Support batten

Perimeter support batten

Perimeter insulation

Moisture barrier (if required)

Construction height

30mm

≤22mm

≤52mm

Technical Data

Construction suitable for rooms on intermediate floors

Construction height

Mass

Thermal resistance, R-value

Uniform Distributed Load (UDL)

Point load (≥ 20cm²)

Impact sound reduction

Area of application

Floors with rooms of equal

temperature above & below

Rmin=0,75 m²K/W

Additional information

mm

≤52

Height without floor finish

kg/m²

3

Mass without floor finish

m²K/W

0.86

Part L compliant for floors above heated rooms

kN/m²

2.0

kN

2.0

dB

-

This construction is suitable for use on intermediate floors, no further insulation is needed to meet the requirements of Approved Document L.

 

For ground floor installations refer instead to construction ID EPS-60G.

Substrate must be solid, level and flat so that the heating elements can lie flat. Tolerance required as per Surface Regularity 1. (+/- 3mm over 2m)

 

30mm support battens to be fitted between heating panels and fixed to substrate if necessary