Construction ID: EPS-60U









Solid timber floor
Direct installation (fixed to battens)
System IDEAL EPS 240 kPa

UDL
2.0 kN/m²
Floor finish
JUPITER IDEAL EPS
Support batten
Perimeter support batten
Perimeter insulation
Moisture barrier (if required)
Construction height

30mm
≤22mm
≤52mm
Technical Data
Construction suitable for rooms on intermediate floors
Construction height
Mass
Thermal resistance, R-value
Uniform Distributed Load (UDL)
Point load (≥ 20cm²)
Impact sound reduction
Area of application
Floors with rooms of equal
temperature above & below
Rmin=0,75 m²K/W
Additional information
mm
≤52
Height without floor finish
kg/m²
3
Mass without floor finish
m²K/W
0.86
Part L compliant for floors above heated rooms
kN/m²
2.0
kN
2.0
dB
-
This construction is suitable for use on intermediate floors, no further insulation is needed to meet the requirements of Approved Document L.
For ground floor installations refer instead to construction ID EPS-60G.
Substrate must be solid, level and flat so that the heating elements can lie flat. Tolerance required as per Surface Regularity 1. (+/- 3mm over 2m)
30mm support battens to be fitted between heating panels and fixed to substrate if necessary
.zip includes:
NBS Spec
.DWG