top of page

Construction ID - EPS-BJ1G

Solid / engineered timber

Direct installation

System IDEAL EPS 240 kPa

UDL

3.0 kN/m²

Timber floors

Construction height

JUPITER IDEAL EPS

Supporting ply

Supporting batten

Joist

Primary insulation i.e Kingspan

18mm

30mm

0mm

Technical Data

Construction suitable for floors above uninsulated or unheated space

Construction height

Mass

Thermal resistance, R-value**

mm

kg/m²

m²K/W

0

4 - 5.5

0.86

System sits between joists avoiding height

Mass excluding floor finish

Part L with correct amount of additional insulation

.zip includes:

.PDF

NBS Spec

.DWG

Uniform Distributed Load (UDL)

Point load (≥ 20cm²)

Impact sound reduction

Area of application

Ground floors or floors located above unheated rooms such as garages, basements etc.

Additional information

kN/m²

3.0

kN

3.0

dB

-

This construction is valid for floor constructions located above uninsulated or unheated space

* Based on 50mm & 100mm Kingspan Kooltherm K103

** R-value of JUPITER IDEAL system only

 

For upper floor installation see construction EPS-BJ1U.

When installing timber floors without tongue and groove edges it is advised to install building paper or similar under timber floor as possible shrinkage of timber will expose aluminium diffuser plates beneath.

 

Glue and screw supporting ply to battens.

 

Aluminium diffuser plates should be flush with top of joists.

bottom of page