Construction ID - EPS-BJ2G









All floor finishes
Screed Replacement Tile
System IDEAL EPS 240 kPa

UDL
5.0 kN/m²

Screed Replacement Tile
Construction height 18mm
JUPITER IDEAL EPS
Supporting ply
Supporting batten
Joist
Primary insulation i.e Kingspan
18mm
30mm
18mm
Technical Data
Construction suitable for floors above uninsulated or unheated space
Construction height
Mass*
Thermal resistance, R-value**
mm
kg/m²
m²K/W
18
40-42
0.86
Height based on S.R.T. thickness
Mass excluding floor finish
Part L compliant for floors above unheated rooms
.zip includes:
NBS Spec
.DWG
Uniform Distributed Load (UDL)**
Point load (≥ 20cm²)***
Impact sound reduction
Area of application
Ground floors or floors located above unheated rooms such as garages, basements etc.
Additional information
kN/m²
5.0
kN
5.0
dB
-
This construction is valid for floor constructions located above uninsulated or unheated space
* Based on 50-100mm of Kingspan Kooltherm K103
* R-value of JUPITER IDEAL heating panel only
***Joist integrity dependent
For upper floor installation see construction EPS-BJ2U.
When installed the Screed Replacement Tiles may follow any undulation that occurs from the joists. This may need to be taken out with the use of a thin levelling compound.
Aluminium diffuser plates should be flush with top of joists.