top of page

Construction ID - EPS-BJ3U

All floor finishes*

Fermacell 2E11

System IDEAL EPS 240 kPa

UDL

2.0 kN/m²

Fermacell 2E11

Construction height

JUPITER IDEAL EPS

Supporting ply

Supporting batten

Joist

18mm

30mm

20mm

20mm

Technical Data

Construction suitable for floors between rooms of equal temperature

Construction height

Mass

Thermal resistance, R-value

mm

kg/m²

m²K/W

20

25

0.86

System height based on Fermacell thickness

Mass excluding floor finish

Part L compliant for floors above heated rooms

.zip includes:

.PDF

NBS Spec

.DWG

Uniform Distributed Load (UDL)

Point load (≥ 20cm²)

Impact sound reduction

Area of application

Floors with rooms of equal

temperature above & below

Rmin=0,75 m²K/W

Additional information

kN/m²

2.0

kN

2.0

dB

-

This construction is valid for floor constructions located between rooms heated to equal or similar temperature. No further insulation is required to meet Part L requirements.

 

For ground floor installation see construction EPS-BJ3G.

When installed the Fermacell elements may follow any undulation that occurs from the joists. This may need to be taken out with the use of a thin levelling compound.

 

Aluminium diffuser plates should be flush with top of joists.

 

*Caution with tile and stone