Construction ID: NEO19-10









Carpet / tiles / timber / laminates / synthetics
Fermacell 2E11 / Gypsum fibre board
System IDEAL NEO19 240 kPa

UDL
2.0 kN/m²

Floor finish
Construction height
Fermacell 2E11
JUPITER IDEAL NEO 19
Perimeter support batten
Perimeter insulation
Moisture barrier (if required)
20mm
19mm
39mm
Technical Data
Construction suitable for rooms with restrcited ceiling height
Construction height
mm
39
Height excluding floor finish
Mass
kg/m²
25
Mass excluding floor finish
Thermal resistance, R-value
m²K/W
0.51
.zip includes:
NBS Spec
.DWG
Uniform Distributed Load (UDL)
Point load (≥ 20cm²)
Impact sound reduction
Area of application
For refurbishment areas with restricted ceiling where minimum insulation requirements are not required
Additional information
kN/m²
2.0
kN
1.0
dB
-
Construction suitable for rooms with restricted ceiling height but does not comply with the minimum insulation level required on intermediate floors.
Should only be used in refurbishment scenarios.
Substrate must be solid, level and flat so that the heating elements can lie flat. Tolerance required as per Surface Regularity 1. (+/- 3mm over 2m)
Fermacell elements are glued & screwed / stapled together as a floating floor.
Installation environment must be min. +10°C max. 40°C
Fermacell material format: 1500mm x 500mm x 20mm
Caution – restrictions apply to maximum tile & stone sizes on Fermacell