top of page

Construction ID: NEO19-60

Solid timber floor

Mechanically fixed to battens

System IDEAL NEO19 240 kPa

UDL

3.0 kN/m²

Floor finish

Construction height

JUPITER IDEAL NEO 19

Support batten

Perimeter support batten

Perimeter insulation

Moisture barrier (if required)

≤22mm

19mm

≤41mm

Technical Data

Construction suitable for floors of with restricted ceiling height

Construction height

mm

41

Height including floor finish

Mass

kg/m²

2

Mass excluding floor finish

Thermal resistance, R-value

m²K/W

0.55

.zip includes:

.PDF

NBS Spec

.DWG

Uniform Distributed Load (UDL)

Point load (≥ 20cm²)

Impact sound reduction

Area of application

For refurbishment areas with restricted ceiling where minimum insulation requirements are not required

Additional information

kN/m²

3.0

kN

2.0

dB

-

Construction suitable for rooms with restricted ceiling height but does not comply with the minimum insulation level required on intermediate floors.

 

Should only be used in refurbishment scenarios.

Substrate must be solid, level and flat so that the heating elements can lie flat. Tolerance required as per Surface Regularity 1. (+/- 3mm over 2m)

bottom of page