top of page

Construction ID: NEO19-70

Adhered tile / timber / vinyl / synthetics

Jupiter Firmax CP

System IDEAL NEO19 240 kPa

UDL

3.0 kN/m²

Floor finish

Construction height

JUPITER Firmax CP

JUPITER IDEAL NEO 19

Perimeter support batten

Perimeter insulation

Moisture barrier (if required)

19mm

12mm

31mm

Technical Data

Construction suitable for floors of rooms with restricted ceiling height

Construction height

mm

31

Height excluding floor finish

Mass

kg/m²

23

Mass excluding floor finish

Thermal resistance, R-value

m²K/W

0.51

.zip includes:

.PDF

NBS Spec

.DWG

Uniform Distributed Load (UDL)

Point load (≥ 20cm²)

Impact sound reduction

Area of application

For refurbishment areas with restricted ceiling where minimum insulation requirements are not required

Additional information

kN/m²

3.0

kN

2.0

dB

-

Construction suitable for rooms with restricted ceiling height but does not comply with the minimum insulation level required on intermediate floors.

 

Should only be used in refurbishment scenarios.

Substrate must be solid, level and flat so that the heating elements can lie flat. Tolerance required as per Surface Regularity 1. (+/- 3mm over 2m)

 

Installation environment must be min. +12°C max. +30°C

 

Firmax CP product format: 1200mm x 600mm x 12mm (2no layers @ 6mm)

Firmax CP mass: 21kg/m²

Firmax CP thermal resistance: 0.038m²K/W

bottom of page