top of page

Construction ID - SS-U

Carpet / tiles / timber / laminates / synthetics

Sand / cement or liquid anhydrite screed

System STANDARD

UDL

2.0 kN/m²

Liquid screed | Sand / cement screed

16mm self adhesive clip rails

Jupiter 16mm multi layer pipe

Intermediate insulation EPS

Perimeter insulation

Moisture barrier (if required)

Sealing strip

30mm

Technical Data

Construction suitable for upper floor constructions

Construction height

Mass

Thermal resistance, R-value

mm

kg/m²

m²K/W

80-95*

110-140

variable

Height excluding floor finish

Mass excluding floor finish

According to primary insulation

.zip includes:

.PDF

NBS Spec

.DWG

Uniform Distributed Load (UDL)

Point load (≥ 20cm²)

Impact sound reduction

Area of application

Floors with rooms of equal

temperature above & below

Rmin=0.75 m²K/W

Installation information

kN/m²

2.0

kN

1.0

dB

≥29

Valid on concrete floors >12cm | (DIN EN 4109: m² > 276kg/m²)

This construction is suitable intermediate floor constructions. No further insulation is required to meet Part L requirements.

 

For ground floor construction see construction SS-G

Services can such as flow and return pipes etc can be run within primary insulation and back filled with loose fill levelling compound..

 

* 80mm includes 50mm liquid screed on 30mm insulation. 95mm includes min. 65mm sand cement screed on typical 75mm insulation. For additional load i.e. 3 kN/m² increase by further 15mm anhydrite or 20mm sand /cement.

 

Strict heating up protocol applies with all ‘in’ screed systems.

bottom of page