Construction ID - SS-U









Carpet / tiles / timber / laminates / synthetics
Sand / cement or liquid anhydrite screed
System STANDARD

UDL
2.0 kN/m²

Liquid screed | Sand / cement screed
16mm self adhesive clip rails
Jupiter 16mm multi layer pipe
Intermediate insulation EPS
Perimeter insulation
Moisture barrier (if required)
Sealing strip
30mm
Technical Data
Construction suitable for upper floor constructions
Construction height
Mass
Thermal resistance, R-value
mm
kg/m²
m²K/W
80-95*
110-140
variable
Height excluding floor finish
Mass excluding floor finish
According to primary insulation
.zip includes:
NBS Spec
.DWG
Uniform Distributed Load (UDL)
Point load (≥ 20cm²)
Impact sound reduction
Area of application
Floors with rooms of equal
temperature above & below
Rmin=0.75 m²K/W
Installation information
kN/m²
2.0
kN
1.0
dB
≥29
Valid on concrete floors >12cm | (DIN EN 4109: m² > 276kg/m²)
This construction is suitable intermediate floor constructions. No further insulation is required to meet Part L requirements.
For ground floor construction see construction SS-G
Services can such as flow and return pipes etc can be run within primary insulation and back filled with loose fill levelling compound..
* 80mm includes 50mm liquid screed on 30mm insulation. 95mm includes min. 65mm sand cement screed on typical 75mm insulation. For additional load i.e. 3 kN/m² increase by further 15mm anhydrite or 20mm sand /cement.
Strict heating up protocol applies with all ‘in’ screed systems.